External references & normal LLM execution
Official sources for the energy problem statement and for explaining how conventional LLM inference works. The IEA figures support the SAIF poster; the technical documentation below supports the Normal Path diagram. These sources are not OPT benchmark measurements.
International Energy Agency (2026). Key Questions on Energy and AI. IEA, Paris.
Figures used on the poster, as stated in the report's executive summary and the accompanying IEA news release:
- Electricity consumption of AI-focused data centres grew by about 50% in 2025.
- Electricity demand of all data centres grew by 17% in 2025.
- Data-centre electricity use is projected to roughly double, from about 485 TWh in 2025 to about 950 TWh in 2030, around 3% of global electricity demand.
Poster wording: "AI-focused data centres used about 50% more electricity in 2025 · total data-centre demand is projected to roughly double by 2030 (IEA, 2026)". The 50% applies to AI-focused data centres only; the doubling is a projection for all data centres.
Official documentation for conventional LLM inference
These four primary technical references document established parts of the Normal Path: API request handling, tokenization and generation, inference scheduling, KV-cache reuse and dynamic batching. They explain common implementation patterns and available features; a specific deployment may enable or disable them.
vLLM. Architecture Overview.
Supports: Request handling, inference scheduling, KV-cache management, GPU workers, model execution and output processing in a conventional serving architecture.
Relevance to the Normal Path: the API / inference-server / GPU-execution stages. This is a technical architecture reference, not an OPT result.
Hugging Face Transformers. Text Generation.
Supports: Loading pretrained models and tokenizers, converting text to model input tokens, generating output tokens and decoding the result.
Relevance to the Normal Path: the tokenizer, LLM inference and response-generation steps. This describes model inference, not a particular OPT run.
vLLM. Automatic Prefix Caching.
Supports: Reusing cached attention key/value (KV) states for eligible shared prompt prefixes, avoiding repeated computation of those prefixes.
Relevance to the Normal Path: the caching stage, when the feature is enabled and a usable prefix exists. Prefix caching is not automatically equivalent to full-response caching.
NVIDIA Triton Inference Server. Batchers / Dynamic Batching.
Supports: Combining compatible inference requests into dynamically formed batches to improve serving throughput and GPU resource utilization when configured.
Relevance to the Normal Path: the batching / inference-scheduling stage. Batching is a standard serving feature, not an OPT-specific technique.
How the NVIDIA and AMD benchmark GPUs are measured
NVIDIA and AMD publish technical interfaces for reading GPU telemetry. The sources below substantiate the monitoring methods and hardware models relevant to the October 2026 OPT laboratory cohort. They are vendor documentation, not independent validation of OPT savings.
Measurement basis: NVIDIA GPU energy (Wh) = (end NVML energy counter in mJ − start counter in mJ) ÷ 3,600,000. AMD GPU energy (Wh) = time-integral of sampled GPU socket power in watts ÷ 3,600. Latency and throughput require separate inference timing instrumentation.
NVIDIA. NVML — Device Queries and Power/Energy Counters.
Supports: Documents nvmlDeviceGetPowerUsage and nvmlDeviceGetTotalEnergyConsumption along with GPU telemetry. NVIDIA readings are device-side, subject to the device/driver's supported features.
Why it matters to OPT: our October V4 NVIDIA cohort used cumulative hardware GPU energy counters; counter differences over the inference window provide measured device energy, rather than a token-based energy estimate.
AMD ROCm. AMD SMI — GPU Metrics and Monitoring.
Supports: Documents AMD GPU monitoring commands and machine-readable metric output, including GPU power where supported. The AMD SMI Python API is also available for supported environments.
Why it matters to OPT: the October MI325X measured-energy cohort used sampled GPU socket power integrated over the execution interval. It is an estimate from physical power telemetry, not a direct NVML counter reading.
NVIDIA. L40S — Official GPU Specifications.
Supports: Official hardware specification for the NVIDIA L40S, one of the four GPU types used in the October V4 experiment.
Hardware specifications establish device capabilities and rated operating limits. They do not determine actual power consumption under a specific OPT workload.
NVIDIA. H100 PCIe — Hopper Architecture and Power Reference.
Supports: NVIDIA's Hopper architecture technical reference covers the H100 PCIe and its device characteristics, including the PCIe variant's TDP.
The H100 PCIe GPU variant must not be confused with the H100 SXM or H100 NVL; the published specification is not an OPT measured energy value.
NVIDIA. RTX A6000 — Official Product Specifications.
Supports: Official product specifications for the NVIDIA RTX A6000, including its maximum power consumption.
Maximum board power is not the same as measured average power or the joules consumed for a benchmark inference request.
AMD. Instinct MI325X — Official Accelerator Specifications.
Supports: Official MI325X accelerator hardware information and board specifications for the AMD GPU tested in October V4.
Rated accelerator power is a hardware specification; OPT's October reported GPU energy came from the experimental socket-power time series.
Global AI superclusters — primary references
Supporting references for the supplied report Global AI Superclusters: GPU Scale, Power & Cost Analysis (November 2026): HUMAIN, Stargate UAE, xAI Colossus, Meta Prometheus and Stargate U.S. The report calculates electricity-cost scenarios using assumed power capacity, utilization and electricity tariffs; these are not metered provider energy figures or actual invoices.
Worked scenario: 1,000,000 kW × 730 hours/month × 70% utilization = 511 million kWh/month. At an assumed flat $0.0552/kWh this equals about $28.2 million/month. The rate is not verified as applicable to all consumption at a hyperscale Saudi facility: tariff categories/tiers, eligibility, VAT, PUE, power-purchase agreements and metering boundaries may change the bill.
HUMAIN / NVIDIA
Documented scope: NVIDIA announces up to 500 MW of planned Saudi AI factories over five years, with several hundred thousand GPUs (planned, not measured draw).
Stargate UAE / OpenAI
Documented scope: OpenAI describes a 1-GW planned cluster with a 200-MW phase expected in 2026; the full gigawatt is not a measured continuous load.
Stargate UAE / G42
Documented scope: G42 describes the 1-GW cluster within a separate 5-GW campus; the two scales must not be conflated.
xAI Colossus
Documented scope: xAI describes its 200,000-H100-GPU cluster and a roadmap to 1 million GPUs; a roadmap is not a present installed count.
Meta Prometheus
Documented scope: Meta describes its gigawatt-scale project and power management, including substantial transient changes in cluster load.
Stargate U.S. / SoftBank
Documented scope: The consortium describes close to 7 GW of planned AI infrastructure capacity at the time of the announcement; planned capacity is not real-time power draw.
Saudi Energy / SEC tariff
Documented scope: Official Saudi electricity tariff categories, tiers and eligibility; do not treat the report's example $0.0552/kWh rate as HUMAIN's verified contract.
Google Data Centers / PUE
Documented scope: Defines facility-wide power usage effectiveness and the importance of data-center overheads; Google's PUE is not a proxy for competitors.
Three measurements that must stay separate
| Metric | Meaning | Not proof of |
|---|---|---|
| Announced GPU count / MW capacity | Current or planned hardware and infrastructure scale as described by the provider | Present electrical draw or billed cost |
| Capacity × load × time × tariff | Illustrative electricity-consumption and cost estimate | Actual utility bills or independently measured provider energy |
| OPT GPU energy (NVML / AMD power integration) | GPU-device-only measured research inference energy | Whole facility consumption, cost, cooling or PUE-adjusted carbon |